The Evaluation of Complications of Titanium Mesh Reconstruction in Orbital Floor Fractures

    Authors

    • Ghufran Majid Hayder
    • Waleed Khalil Ismael

    AL-Yarmook Teaching Hospital, Baghdad, Iraq

,

Document Type : Research Paper

10.52573/ipmj.2021.167828
  • Article Information
  • References
  • Download
  • Export Citation
  • Statistics
  • Share

Abstract

BACKGROUND:
The facial symmetry is a specific measure of bodily symmetry and it influences judgements of aesthetic traits, therefore special attention and care must payed during orbital fracture treatment to consider every detail in the scenario of surgical reconstruction. Many materials have been used for treatment of orbital bones fractures and titanium mesh is widely used implant for this purpose therefore it worthwhile to study it.
AIM OF STUDY:
Evaluate the complications of using titanium mesh in the treatment of orbital floor fractures.
MATERIALS AND METHODS:
The study included 13 patients (11 males and 2 females) presented to Oral and Maxillofacial Surgical Department in Al-Yarmook Teaching Hospital Iraq/ Baghdad in the period from January 2018 to June 2019 with traumatic orbital floor fracture and they underwent reconstruction with titanium mesh.
RESULTS:
The results showed that the most common cause for trauma was road traffic accident (53.8%). Preoperative diplopia found in 12 patients (92.31%) followed by persistent diplopia found in only one (7.69%). Preoperative enophthalmos was (61.5%) in eight patients, six of them improved after treatment and returned to the normal condition but only two had postoperative enophthalmos with less severity.
CONCLUSION: 
The reconstruction of orbital floor using titanium mesh was successful in most of the cases and the resulted was good and satisfactory aesthetic and functional results.
 

Keywords

  • Orbital fracture
  • titanium mesh
  • diplopia
  • enophthalmous
  • Hertel exophthalmometer
  • XML
  • PDF 283.07 K
  • RIS
  • EndNote
  • Mendeley
  • BibTeX
  • APA
  • MLA
  • HARVARD
  • VANCOUVER
References
  1. Al-Anezi M, Mahran H, Alomaym M, Salma Albati S, Alharbi M. Role of Titanium Mesh as aReconstruction Material for Orbital Floor Defects in Cases of Orbital Blowout Trauma, OHDM- 2018:17.
  2. Breme J, Steinhäuser E, Paulus G: Commercially pure titanium Steinhäuser plate screw system for maxillofacial surgery. Biomaterials 1988;9:310-13.
  3. Brennan PA, Schliephake H, Ghali GE. Maxillofacial Surgery .2017, 3rd edition, volume1
  4. Fonseca R J. Oral and Maxillofacial trauma 4th edition, 2013.
  5. Gabrielli M F., Monnazzi M S, Passeri L A, Carvalho W R, Orbital Wall Reconstruction with Titanium Mesh. Craniomaxillofac Trauma Reconstr, 2011;4:151–56.
  6. Hoffmann J, Cornelius CP, Groten M, Pröbster L, Pfannenberg C, Schwenzer N. Orbital reconstruction with individually copymilled ceramic implants. Plast Reconstr Surg, 1998;101:604–12.
  7. Ling-Xiao Ye, Xiao-Ming Sun, Yu-Guang Zhang, Ying Zhang. Materials to facilitate orbital reconstruction and soft tissue filling in posttraumatic orbital deformities,Plast Aesthet Res 2016; 3:86-91.
  8. Perry M, Brown A, Banks P.Fractures Of The Facial Skeleton, 2016. Second Edition.
  9. Rubin PA, Shore JW, Yarmechuk.  Complex Orbital Fracture Repaire Using rigid fixation of internal orbital skeleton. Ophthalmology, 1992.

10. Scolozzi P,Momjian A, Heuberger J, Andersen E,‏Broome M, Terzic A, Jaques B, Accuracy and Predictability in Use of AO Three-Dimensionally Preformed Titanium Mesh Plates for Posttraumatic Orbital Reconstruction: A Pilot StudyJ Craniofac Surg 2009;20:1108Y1113.

    • Article View: 350
    • PDF Download: 245
Iraqi Postgraduate Medical Journal
Volume 20, Issue 1
January 2021
Page 67-71
Files
  • XML
  • PDF 283.07 K
Share
Export Citation
  • RIS
  • EndNote
  • Mendeley
  • BibTeX
  • APA
  • MLA
  • HARVARD
  • VANCOUVER
Statistics
  • Article View: 350
  • PDF Download: 245

APA

Hayder, G., & Ismael, W. (2021). The Evaluation of Complications of Titanium Mesh Reconstruction in Orbital Floor Fractures. Iraqi Postgraduate Medical Journal, 20(1), 67-71. doi: 10.52573/ipmj.2021.167828

MLA

Ghufran Majid Hayder; Waleed Khalil Ismael. "The Evaluation of Complications of Titanium Mesh Reconstruction in Orbital Floor Fractures". Iraqi Postgraduate Medical Journal, 20, 1, 2021, 67-71. doi: 10.52573/ipmj.2021.167828

HARVARD

Hayder, G., Ismael, W. (2021). 'The Evaluation of Complications of Titanium Mesh Reconstruction in Orbital Floor Fractures', Iraqi Postgraduate Medical Journal, 20(1), pp. 67-71. doi: 10.52573/ipmj.2021.167828

VANCOUVER

Hayder, G., Ismael, W. The Evaluation of Complications of Titanium Mesh Reconstruction in Orbital Floor Fractures. Iraqi Postgraduate Medical Journal, 2021; 20(1): 67-71. doi: 10.52573/ipmj.2021.167828

  • Home
  • About Journal
  • Editorial Board
  • Submit Manuscript
  • Contact Us
  • Glossary
  • Sitemap

News

This work is licensed under          CC BY 4.0    

 

 

Newsletter Subscription

Subscribe to the journal newsletter and receive the latest news and updates

© Journal Management System. Powered by iJournalPro.com